18.2.2 Removing the burner

1. Carry out step 18.1.1 and 18.2.1;
2. Remove the 3 screws F from the
air/gas manifold (Fig. 57);
F

18.2.3 Removing the detection electrode

1. Carry out step 18.1.1;
2. Remove the 2 screws G from the
electrode manifold (Fig. 60);
G

18.2.4 Removing the ignition electrode

1. Carry out step 18.1.1;
2. Remove the earth cable from the
electrode (Fig. 63);
3. Slide the burner out from the
front, taking care not to damage the
insulation (Fig. 58);
Fig. 57
3. Pull the electrode from the
combustion chamber (Fig. 61);
Fig. 60
3. Remove the electrode cable H from
the ignitor (Fig. 64);
H
Fig. 63
4. Reassemble in reverse order and
checking all seals are undamaged
and the burner is positioned
correctly (Fig. 59).
Fig. 58
4. Disconnect the detection electrode
cable (Fig. 62).
5. Reassemble in reverse order.
Fig. 61
4. Unscrew the 2 screws I on the
electrode (Fig. 65);
I
Fig. 64
Fig. 59
Fig. 62