Adjusting The Horizontal Magnetic/Micr Closing Flap - Olivetti PR2 PLUS Service Manual

Table of Contents

Advertisement

Adjusting the horizontal magnetic/MICR closing flap

MACHINE STATUS
– Printer switched off and without casing..
– Read/write carriage in reset position (end of stroke motor side) and screw (1) which joins the semi tie-rods
loosened.
CONDITIONS TO BE CHECKED
Co-planarity between the closing flap and the front surface of the structure.
PROCEDURE
Position the flap (2) in contact with the slot (3) operating in the compartment between the fork and toothing of
the semi tie-rods (4); then, tighten the screw (1).
Adjusting the horizontal magnetic/MICR closing flap
Figure 6 - 11
6-12
1
4
Adjustment
area
Service Manual
3
2
XZAC4219-05