Troubleshooting
If the projector appears to be operating erratically, try to diagnose and
correct the problem, using the following guide. If the problem still persists,
consult with qualified Sony personnel.
Symptom
Cause
The power is not turned on.
The power has been turned off and on
with the ON key at a short interval.
The lamp cover is detached.
The air filter cover is detached.
No picture and no sound.
Cable is disconnected.
Input selection is not correct.
No picture or no sound.
Either the picture or the sound is cut
off.
The picture is noisy.
Noise may appear on the background
depending on the combination of the
numbers of dot input from the
connector and numbers of pixel on the
LCD panel.
When inputting sound through the
Monaural sound is being input through
INPUT A/B/C connector, sound
the INPUT A/B/C connector.
comes through one channel only.
The picture from INPUT A/B/C
Setting for INPUT-A, INPUT-B or
connector is colored strange.
INPUT-C in the SIGNAL SELECT
menu is incorrect.
"Please check INPUT-A in SIGNAL
Setting for INPUT-A in the SIGNAL
SELECT" appears in spite of
SELECT menu is incorrect.
inputting the correct signal from
INPUT A.
"Please check INPUT-B in SIGNAL
Setting for INPUT-B in the SIGNAL
SELECT" appears in spite of
SELECT menu is incorrect.
inputting the correct signal from
INPUT B.
"Please check INPUT-C in SIGNAL
Setting for INPUT-C in the SIGNAL
SELECT" appears in spite of
SELECT menu is incorrect.
inputting the correct signal from
INPUT C.
"NO INPUT" appears when 15k RGB
The sync signal is incorrect.
or component signal is input.
On-screen displays do not appear.
STATUS in the SET SETTING menu is
set to OFF.
Color balance is not correct.
Picture has not been adjusted
properly.
The color system of the input signal is
not set correctly.
The picture is too dark.
The lamp is nearing the end of its life.
Contrast or brightness has not been
adjusted properly.
The picture is not clear.
The picture is out of focus.
Moisture condensation has occurred
on the lens.
50
(GB)
Remedy
Wait for about 30 seconds before turning on
the power (see page 10 (GB)) .
Attach the lamp cover securely.
Attach the air filter cover securely (see page
49 (GB)) .
Check that the proper connections have been
made (see pages 20 (GB), 42 (GB) and 43
(GB)) .
Select the input source correctly in the
SIGNAL SELECT menu (see page 32 (GB)) .
Press the MUTING key to cancel the muting
function (see page 10 (GB)) .
Change the desktop pattern on the connected
computer.
Input stereo sound.
Set INPUT-A, INPUT-B or INPUT-C in the
SIGNAL SELECT menu correctly according to
the input signal (see page 32 (GB)) .
Set INPUT-A in the SIGNAL SELECT menu
correctly according to the input signal (see
page 32 (GB)) .
Set INPUT-B in the SIGNAL SELECT menu
correctly according to the input signal (see
page 32 (GB)) .
Set INPUT-C in the SIGNAL SELECT menu
correctly according to the input signal (see
page 32 (GB)) .
Input the correct sync singal (composite sync
or sync on G singal (sync on Y for component
singal)).
Set STATUS in the SET SETTING menu to
ON (see page 30 (GB)) .
Adjust the picture (see pages 25 and 26 (GB)) .
Set COLOR SYS in the PICTURE CTRL menu
to match the color system of the input signal
(see page 26 (GB)) .
Replace the lamp with a new one (see page
48 (GB)) .
Adjust CONTRAST or BRIGHT in the
PICTURE CTRL menu properly (see page 25
(GB)) .
Adjust the focus (see page 22 (GB)) .
Leave the projector for about two hours with
the power on (see page 18 (GB)) .
Symptom
Cause
The Remote Commander does not
The batteries are exhausted.
work.
The remote commander cable is
connected to the Remote Commander
although you are using it as a wireless
Remote Commander.
The fluorescent lamp influences on the
Remote Commander detector.
You have selected a wrong index
number.
You have set the index number to "00".
The wireless Remote Commander
The SIRCS RECEIVER setting is not
does not function.
correct.
The switcher is not connected, but is
INPUT A cannot be selected.
recognized to be connected.
The COVER FAIL indicator lights.
The lamp cover or air filter cover is
detached.
The lamp with the same number of the
The LAMP FAIL indicator lights.
indicator has reached the end of its
life.
The fan is broken.
The FAN indicator lights.
The HIGH TEMP indicator lights.
The internal temperature is unusually
high.
The lens control function is locked.
When you press the ZOOM, SHIFT
or FOCUS key, "LENS CONTROL
is locked! Do you wish to unlock ?"
appears.
Caution messages
Use the list below to check the meaning of the messages displayed on the
screen.
Meaning
Message
Internal temperature becomes too high.
High Temperature!
Power off in 1 min.
The frequency of the input signal is out
Frequency is out of range!
of the acceptable range.
You have input the RGB signal from
Please check INPUT-A in SIGNAL
the computer when INPUT-A in the
SELECT.
SIGNAL SELECT menu is set to
COMPONENT or YP
You have input the RGB signal from
Please check INPUT-B in SIGNAL
the computer when INPUT-B in the
SELECT.
SIGNAL SELECT menu is set to
COMPONENT or YP
You have input the RGB signal from
Please check INPUT-C in SIGNAL
the computer when INPUT-C in the
SELECT.
SIGNAL SELECT menu is set to
COMPONENT or YP
Remedy
Replace the batteries with new ones (see
page 17 (GB)) .
Disconnect the remote control cable.
Change the setting of SIRCS RECEIVER in
the SET SETTING menu (see page 31 (GB)) .
Select the correct index number (see pages 31
(GB) and 45 (GB)) .
Select the correct index number (see page 45
(GB)) .
Change the setting of SIRCS RECEIVER in
the SET SETTING menu (see page 31 (GB)) .
If the PJ COM connector is connected to
something other than the terminator, remove it
then press the SYS SET key.
Attach the lamp cover or air filter cover
securely (see pages 48 (GB) and 49 (GB)) .
Replace the lamp (see page 48 (GB)) .
Consult with qualified Sony personnel.
Check to see if nothing is blocking the
ventilation holes.
Consult with qualified Sony service personnel.
Remedy
Turn off the power. (If not, the power is
automatically turned off about one minute
later.) Check to see if nothing is blocking the
ventilation holes.
Input a signal that is within the range of the
frequency.
Set INPUT-A correctly.
P
.
B
R
Set INPUT-B correctly.
P
.
B
R
Set INPUT-C correctly.
P
.
B
R
51