Boiler Connection - Fujitsu WOxK112LCT Design & Technical Manual

High power series (3 phase type) air to water split type
Table of Contents

Advertisement

Interconnection between the outdoor
unit and the indoor unit
Comply with the correspondence between the
markings on the indoor unit's terminals and
those on the outdoor unit when connecting the
interconnection cables.
A connection error could cause the destruction of
one or other of the units.
Electric back-ups
If the heat pump is not installed with a boiler
connection:
-
Connect the electrical supply for the back-ups to
the electrical panel.

Boiler connection

-
Please refer to the instructions supplied with the
boiler connection kit.
-
Please refer to the instructions supplied with the
boiler.
Domectic hot water tank
If the installation is fitted with a DHW tank with
electrical back-up heating:
-
Please refer to the instructions supplied with the
DHW kit.
-
Please refer to the instructions supplied with the
DHW tank.
Second heating circuit
-
Please refer to the instructions supplied with the
second circuit kit or / and Regulation extension
kit.
Contract with the power provider
The heat pump's operation can be controlled to suit
special contracts (e.g. Low-tariff, day/night).
In particular, domestic hot water (DHW) at Nominal
temperature will be produced during the off-peak
hours when electricity is cheaper.
-
Connect the "Power Provider" contact to input
EX2.
-
Set the parameter line 1620 to "Low-tariff".
-
230V on input EX2 = "Peak hours" information
activated.
Power limitation or EJP
(peak day removal)
Power limitation is intended to reduce electrical
consumption when this is too high compared to the
contract with the power provider.
-
Connect the power limiting device to input EX,
the back-ups for the heat pump and the DHW
stop in the event of over-consumption by the
dwelling.
-
230 V on input EX1 = power limitation in
progress.
External faults the heat pump
Any component of carryforward of information
(thermostat, pressure switch, etc.) may signal an
external problem and stop the heat pump.
-
Connect the external component to input EX3.
-
230 V on input EX3 = stoppage of heat pump
(the system displays Error 369).
-
In the case of a heated floor, connect the floor
heating safety device into the connector of the
floor heating pump.