FUNCTIONS

2-13
USER INTERFACE
AND REMOTE CONTROL (Optional parts)
1
2
3
4
Ref 3
Functions
1
Selecting DHW operating mode
(Domestic Hot Water)
2
Digital display
3
Exit "ESC"
4
Navigation and setting
5
Selecting heating mode
5
6
7
8
9
- Definitions
-
If the installation is fitted with a DHW tank.
-
On : Production of DHW according to the time program.
-
Off : Preparing the domestic hot water for stopping with the
On
anti-frost function active.
-
Manual start button : Hold down the DHW key for 3 seconds.
Off
Switch from "reduced" to "comfort" until the next time the
DHW timer switches over.
-
Operating control. Readout of the current temperature, the
heating mode and any faults
-
View the settings
-
Quit the menu.
-
Selecting the menu.
-
Setting parameters.
-
Adjusting the ambient temperature setpoint.
-
Auto
Heating operation according to the heating program
(Summer/Winter mode switchover is automatic).
-
Constant comfort temperature.
-
Constant reduced temperature.
-
Stand-by mode with anti-frost protection
(Provided that the heat pump's electrical power supply is not
interrupted).
- (CS01 - 03) -
1
Auto
2
0
4
8
1 2
1 6
2 0
2 4
3
ESC
OK
4
6
.
5
7
12
8
Control system