5.3 Setting continuous temperatures

Instead of the clock program, you can also set the room temperature continuously to a particular
value. You can set three different continuous temperatures via Menu > Program:
Day temp.: room temperature during the day, corresponding to the "Continuous day"
program.
Night temp.: room temperature at night, corresponding to the "Continuous night" program.
Frost temp.: room temperature to protect the room where the controller is installed from
freezing. This setting comes under the "Frost protected" program.
i
The programs mentioned are explained in paragraph 6.1.

5.4 Group control

With the aid of the c-Mix, the iSense can control two groups; both groups can be assigned
their own program and control strategy. This is done via: Menu>Settings>System>Central
Heating system>Groups "no groups" is the default setting.
The option "1&2 separately" can be used to assign each group its own program.
The icon will appear in the standard screen. You can then press the rotary knob/pushbutton to
switch between control of group 1 and group 2.
If "2 follows 1" is selected, both groups are assigned their own strategy, but group 2 will
follow the program for group 1.