3.3 Location of the outside sensor

An outside temperature sensor is not supplied as standard with the iSense.
You only require this sensor if you want weather-compensated control of the inside temperature.
The following guidelines apply with regard to choosing a location for an outside temperature sensor:
Install the outside sensor on the north or north-west side of the home, away from direct sunlight.
The sensor must be positioned at least 2.5 metres above ground level.
Do not install the outside sensor near windows, doors, ventilation grills, extractors, etc.
Consult the documentation for your boiler for information on connecting an outside temperature
sensor.