Sense Inputs; Relay/Trigger Outputs - RTI Under Control XP-8 Installation And Operation Manual

Advanced control processor
Table of Contents

Advertisement

XP-8
Advanced Control Processor
CHAPter 4 | COnneCtIOn OPtIOns

sense InPuts

sense InPuts
Sense contact closure or voltage trigger input (2-12VDC). Sense input
mode can be configured within Integration Designer™. Upon sensing
contact closure or trigger input, events can be automatically triggered such
as IR commands, macros, relay closure, etc.
Wiring for contact closure sense: connect conductors from device to be
sensed to each side of a sense input (A and B).
Wiring for voltage trigger sense: Connect positive lead from voltage
source to Side A of sense input and negative lead to Side B.

relAy/trIGGer OutPuts

Optional accessories shown
are sold separately.
relAy/trIGGer OutPuts
Configurable within Integration Designer™ to be either a dry contact
closure or a voltage trigger output (12VDC @100mA). All relays are
Normally Open when not energized, but they can be programmed to
behave Normally Closed (as long as power is applied to the XP-8).
For contact closure control, simply connect the A and B contact terminals
of a relay to the desired device.
To use a relay as a voltage trigger, connect Contact A to the positive side
and connect Contact B to the ground side of the desired device.
18
Examples:
+ -
Security
Receiver
Examples:
+ -
+ -
Optional accessories shown
are sold separately.
+ -
Screen Lift
Drapes