Ir/Serial Port: Connections And Wiring - AMX NX-1200 Hardware Reference Manual

Nx-series netlinx integrated controllers
Table of Contents

Advertisement

I/O Port Wiring Specifications
NX-3200/4200
Pin Signal
1
GND
2
I/O 1
3
I/O 2
4
I/O 3
5
I/O 4
6
12 VDC
7
GND
8
I/O 5
9
I/O 6
10
I/O 7
11
I/O 8
12
12 VDC
In the above table, pin 1 is located on the right side of the port, and the pinouts count up to the left.

IR/SERIAL Port: Connections and Wiring

The IR/SERIAL ports provide IR transmit/one-way serial connections that support high-frequency carriers up to 1.142
MHz. You can simultaneously generate up to eight IR/Serial data signals on the NX-4200 and NX-3200, up to four on
the NX-2200, and up to two on the NX-1200.
These ports accept an IR Emitter (CC-NIRC) that mounts onto the device's IR window, or a mini-plug (CC-NSER) that
connects to the device's control jack. You can also connect a data 0 - 5 VDC device to these ports.
NX-3200 and 4200 units each ship with two CC-NIRC IR Emitters (FG10-000-11). NX-1200 and 2200 units ship with
one emitter each.
FIG. 19 displays the IR/SERIAL ports for each NX-series controller.
NX-3200/4200
FIG. 19
IR/SERIAL connector (male)
Note: The maximum baud rate for ports using DATA mode is 19200. Also, DATA mode works best when using a short
cable length (< 10 feet).
Note: For each data signal, the negative (-) terminal is for Signal GND, and the positive (+) terminal is for IR/Serial
data.
Hardware Reference Guide - NX-Series NetLinx Integrated Controllers
NX-1200/2200
Function
Pin Signal
Signal GND
1
GND
Input/Output
2
I/O 1
Input/Output
3
I/O 2
Input/Output
4
I/O 3
Input/Output
5
I/O 4
PWR
6
12 VDC
Signal GND
Input/Output
Input/Output
Input/Output
Input/Output
PWR
Function
Signal GND
Input/Output
Input/Output
Input/Output
Input/Output
PWR
NX-2200
Wiring and Connections
NX-1200