Electrical Connection - Rangemaster Toledo XT 110 Dual Fuel User's Manual & Installation Instructions

Hide thumbs Also See for Toledo XT 110 Dual Fuel:
Table of Contents

Advertisement

Pressure Testing
The gas pressure can be measured at one of the hotplate
burner injectors (not a wok burner).
Lift off a burner head. Fit the pressure gauge to the injector.
Turn on and light one of the other hotplate burners.
Turn on the control knob for the burner with the pressure
gauge fitted to let gas through.
See the data badge for test pressures.
Turn off the burners. Make sure that you reassemble the
burner top in the correct way on the burner body.

Electrical Connection

The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
The cooker MUST not be connected to an ordinary
n
n
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (
and
Fig.7.11
Fig.7.12
fitted and that the terminal screws are tight. Secure the mains
cable using the cable clamp.
Check the appliance is electrically safe and gas sound when you have finished.
). Check that the links are correctly
INSTALLATION
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
26
26
Fig.7.11
6 mm² max
Fig.7.12
6 mm² max
10 mm² max

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents