11-2-1. Outdoor Interface P.C. Board

Dip switch function exchange setup list

Part type
SW01 Rotary SW 4bit 16 step Display / Operation switch (1)
SW02 Rotary SW 4bit 16 step Display / Operation switch (2)
SW03 Rotary SW 4bit 16 step Display / Operation switch (3)
SW04 Push SW
SW05 Push SW
SW06 SW 4bit
SW07 SW 4bit
SW08 SW 1bit
SW09 SW 4bit
SW10 SW 4bit
SW11 SW 4bit
SW12 SW 4bit
SW13 SW 4bit
SW14 SW 4bit
SW30 SW 2bit
CN30 Check connector
CN31 Check connector
CN32 Check connector
* The outdoor unit connected with indoor/outdoor communication line becomes automatically the master unit.
No manual setting is necessary.
For service [Operation/Start]
For service [Stop/End]
Bit 1
Backup setup
Bit 2
Bit 4
Bit 3
Bit 3
OFF
OFF
Bit 4
Bit 1 Power peak-cut control exchange
Bit 2 Power peak-cut control exchange (Expansion) (For 4-steps exchange)
Bit 3
Bit 4
Bit 1 High humidity condition setting
Bit 1
Bit 2 Judge indoor capacity over
Bit 3
Bit 4 Judge abnormal No. of connected indoor units OFF: No error judgment, ON: Error
Bit 1
Bit 2
Bit 3
Sound reduction control
Bit 4
Bit 1
Bit 2
Bit 3
Bit 4 Operation when indoor overflow detected
Bit 1 PMV manual operation selected
Bit 2
Bit 3
Bit 4
Bit 1
Bit 2
Bit 3
Bit 4 Line address setup
Bit 1, 2, 3, 4
Line address setup
Bit 2 Terminator resistor between outdoor units
Manual full opening setup of PMV
Manual full closing setup of PMV
Check for assembly line in factory.
Exchange contents
For 7-segment display / service operation
For 7-segment display / service operation
For 7-segment display / service operation
[Operation/Start] by pushing
[Stop/End] by pushing
(Based on the following setup)
Bit 2
Bit 1
OFF
OFF
Normal
OFF
ON
No.1 COMP backup
ON
OFF
No.2 COMP backup
OFF: 0 – 100%, ON: Middle – 100%
OFF: YES (Normal), ON: NO
OFF: Normal,
ON : INV frequency upper limit restriction
OFF: Normal, ON: Fan rpm upper limit restriction
OFF: System stop,
ON : System operation continues
OFF: PMV
Refer to item "Address setup procedure"
OFF: No Terminator resistor
ON : Exists
Opened: Normal, Short: Opened fully
Opened: Normal, Short: Opened fully
Opened: Normal, Short: Check mode
165
Initial setup
at shipment
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
Open
Open
Open
[1]
[1]
[1]