NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection
than what is displayed here. Always verify with your electrical service contractor that your circuit protection is ade-
quate and meets all applicable national and local codes. These numbers are provided in this manual simply for ref-
erence and may change without notice at any given time.
TEMPSTAR/TEMPSTAR SDS:
RINSE
HEATER
VOLTS PH
HZ
RATINGS
208
1
50
12KW@240V
208
1
50
14KW@240V
230
1
50
12KW@240V
230
1
50
14KW@240V
208
3
50
12KW@240V
208
3
50
14KW@240V
230
3
50
12KW@240V
230
3
50
14KW@240V
380
3
50
12KW@380V
380*
3
50
14KW@208V
415
3
50
12KW@415V
415
3
50
14KW@415V
440
3
50
12KW@460V
440
3
50
14KW@460V
208
1
60
12KW@240V
208
1
60
14KW@240V
230
1
60
12KW@240V
230
1
60
14KW@240V
208
3
60
12KW@240V
208
3
60
14KW@240V
230
3
60
12KW@240V
230
3
60
14KW@240V
460
3
60
12KW@480V
460
3
60
14KW@480V
* This model is wired in a wye configuration for the heaters.
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
TYPICAL
TOTAL
ELECTRICAL
AMPS
CIRCUIT
71 A
90 AMP
78 A
100 AMP
78 A
100 AMP
86 A
110 AMP
45 A
60 AMP
49 A
70 AMP
48 A
60 AMP
53 A
70 AMP
29 A
40 AMP
34 A
45 AMP
26 A
35 AMP
29 A
40 AMP
21 A
30 AMP
25 A
35 AMP
69 A
90 AMP
76 A
100 AMP
76 A
100AMP
84 A
110 AMP
43 A
60 AMP
47 A
60 AMP
46 A
60 AMP
51 A
70 AMP
22 A
30 AMP
25 A
35 AMP
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
TEMPSTAR LT/TEMPSTAR NB:
VOLTS PH
HZ
208
1
50
230
1
50
208
3
50
230
3
50
380
3
50
415
3
50
440
3
50
208
1
60
230
1
60
208
3
60
230
3
60
460
3
60
TEMPSTAR S:
VOLTS PH
HZ
208
1
60
230
1
60
208
3
60
230
3
60
3
RINSE
TYPICAL
HEATER
TOTAL
ELECTRICAL
RATINGS
AMPS
CIRCUIT
N/A
28 A
35 AMP
N/A
30 A
40 AMP
N/A
20 A
25 AMP
N/A
21 A
30 AMP
N/A
10 A
15 AMP
N/A
10 A
15 AMP
N/A
8 A
15 AMP
N/A
26 A
35 AMP
N/A
28 A
35 AMP
N/A
18 A
25 AMP
N/A
28 A
35 AMP
N/A
8 A
15 AMP
RINSE
TYPICAL
HEATER
TOTAL
ELECTRICAL
RATINGS
AMPS
CIRCUIT
N/A
6 A
15 AMP
N/A
6 A
15 AMP
N/A
6 A
15 AMP
N/A
6 A
15 AMP