OPERATING CAPACITIES

PERFORMANCE/CAPABILITIES
OPERATING CAPACITY (RACKS/HOUR)
RACKS PER HOUR
DISHES PER HOUR
GLASSES PER HOUR
OPERATING CYCLE (SECONDS)
WASH TIME
RINSE TIME
TOTAL CYCLE
TANK CAPACITY (GALLONS)
WASH TANK (MINIMUM)
BOOSTER TANK
WASH PUMP CAPACITY
GALLONS PER MINUTE
TEMPERATURES
WASH---°F (MINIMUM)
RINSE---°F (MINIMUM)
WASH---°F (MINIMUM) (200 LT)
RINSE---°F (MINIMUM) (200 LT)
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to
change without notice.
STEAM REQUIREMENTS
COIL SIZE
STEAM FLOW PRESSURE (P.S.I.)
CONSUMPTION @ 15 P.S.I. (LBS/HR)
WATER REQUIREMENTS (MINIMUM)
INLET TEMPERATURE (200)
INLET TEMPERATURE (200B)(40° Rise)
INLET TEMPERATURE (200B)(70° Rise)
INLET TEMPERATURE (200LT)
INLET TEMPERATURE (200S)
GALLONS PER HOUR
GALLONS PER RACK
WATER LINE SIZE NPT
DRAIN LINE SIZE NPT
FLOW PRESSURE P.S.I. (Optimum)
MINIMUM CHLORINE REQUIRED (PPM)(200LT)
200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HP
57
1425
NOTE: Typical Electrical Circuit is based upon (1) 125% of
1425
the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition.
Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical
45
service contractor that your circuit protection is adequate
11
and meets all applicable national and local codes. These
58
numbers are provided in this manual simply for reference
and may change without notice at any given time.
8.0
MODEL
VOLTS PH HZ
3.0
200B
208
200B
230
200B
208
200B
230
150
200B
460
200B
208
200B
230
200B
208
150
200B
230
180
200B
460
130
130
200
208
200
230
200
208
200
230
200
460
200/LT
208
200/LT
230
200/LT
208
200/LT
230
3/4"
200/LT
460
10-20
45
200S
208
200S
230
200S
208
200S
230
180°F
200S
460
140°F
110°F
140°F
110°F
52.2
0.92
3/4"
1 1/2"
20A5
50
2
RINSE
HEATER
TOTAL
RATINGS
AMPS
1
60
12KW@230
72 A
1
60
12KW@230
79 A
3
60
12KW@230
40 A
3
60
12KW@230
44 A
3
60
12KW@230
22 A
1
60
14KW@230
79 A
1
60
14KW@230
87 A
3
60
14KW@230
44 A
3
60
14KW@230
49 A
3
60
14KW@230
25 A
1
60
N/A
29 A
1
60
N/A
31 A
3
60
N/A
15 A
3
60
N/A
16 A
3
60
N/A
8 A
1
60
N/A
29 A
1
60
N/A
31 A
3
60
N/A
15 A
3
60
N/A
16 A
3
60
N/A
8 A
1
60
N/A
7 A
1
60
N/A
7 A
3
60
N/A
4 A
3
60
N/A
4 A
3
60
N/A
4 A
1
TYPICAL
ELECTRICAL
CIRCUIT
90 AMP
100 AMP
50 AMP
60 AMP
25 AMP
100 AMP
110 AMP
60 AMP
70 AMP
36 AMP
40 AMP
40 AMP
20 AMP
20 AMP
15 AMP
40 AMP
40 AMP
20 AMP
20 AMP
15 AMP
15 AMP
15 AMP
15 AMP
15 AMP
15 AMP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

200lt200200s

Table of Contents