RINSE REGULATING THERMOSTAT REPLACEMENT
Removing the imperial brass fitting.
Pulling the thermostat probe and fitting from the well.
Removing the wires from the thermostat.
200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)
SECTION 5: SERVICE PROCEDURES
Attaching the jumper wires.
5. Attach the jumper wires to the wires that you removed from
the old thermostat.
Sliding imperial fitting onto new thermostat.
6. Slide the new imperial brass fitting from your kit onto the
new thermostat.
Putting the new thermostat in the well.
24