The network connections auto-sense whether standard or crossover Cat-5e cables are in use. Pre-made
cables with moulded RJ45 plugs are recommended. If it is necessary to make up custom Cat-5e network
cables, use pinout described in Table 7-2.
When the device is connected to an active network, the yellow LINK LED illuminates above the connector in
use. Data activity on the network is indicated by illumination of the green ACT LED. It is normal for the ACT
LED to flicker either sporadically or continuously.
7.3.1
Primary Network Connection
The Primary Network connection is used for Lake Controller connectivity and Dante digital audio. Please
refer to section 4.2 for additional information.
ACT
PRIM
LINK
ACT
SWITCHED 100/1000 Base-T
Figure 7-9: etherCON Network Connectors
Pin No.
Color
1
Brown
2
Brown + White
3
Green
4
Blue + White
5
Blue
6
Green + White
7
Orange
8
Orange + White
Table 7-2: RJ45 Wiring & Pin Out Description
Figure 7-10: RJ45 Wiring and Pin Out Diagram
SEC LINK
LM 26 Operation Manual rev 1.2.3
Back Panel Interface