GPI Configuration
To adjust GPI 1 or GPI 2, press the associated button to display a screen similar to that shown in Figure 6-19.
Table 6-4 lists the options available for General Purpose Input (GPI). These options can be set independently
for a transition from closed > open and from open > closed.
A change to the 'Acting on' setting takes effect the next time the transition occurs. For example, changing a
GPI closed to open transition when the selected GPI is currently open is not executed until the next transi-
tion to open.
A change in GPI open/closed state occurring when
the LM 26 is disconnected from power will be
acknowledged and executed when power is
reconnected.
Figure 6-19: GPI Configuration
Acting on
Transition Option
1. No Action
2. Toggle State
Protective Mute State
3. Mute
4. Unmute
1. No Action
2. Toggle State
Standby State
3. Standby
4. Turn On
1. No Action
Preset Recall
2. Recall #99
3. Recall #100
No Action
-
Table 6-4: GPI Options