Front Panel Interface
The main section of the I/O Status View displays status and metering information for the four input
routers. The information displayed for each input includes the currently selected input source type, input
gain level meter (displayed as a horizontal bar and as numeric dB), input mute status, analog headroom,
digital sample rate, digital clock selection and digital clock locking status.
If an LM 26 input is muted, the top-right LED is illuminated red as shown in Figure 6-6, and the frame fault
text in section A of the screen will display INPUT MUTE. The fault and warning LED illuminates red or
yellow in all Meter and Menu Views as described in section .
These buttons allow muting/unmuting of the associated input. Confirmation of each input's mute status
is displayed on the LCD next to the associated button as shown for input 2 in Figure 6-6.
The faults and warnings LED is accompanied by text on the top-right side of the LCD. The LED illumi-
nates red if any input is muted, or if another fault condition occurs; it illuminates yellow if a warning condition
arises. Please refer to section 6.7.2 for further details.

6.10 Menu Mode

6.10.1 Overview
The majority of functions can be accessed via Menu Mode on the front panel. These functions include
the adjustment of gain, delay, limiters, input and output routing, and the ability to recall Frame Presets.
Menu Mode can be accessed at any time by pressing the MENU button.
After pressing the MENU button, various submenu options are displayed as shown in Figure 6-7 .
Figure 6-7: Menu Mode > Main Menu
Press the illuminated button adjacent to the required option to display an associated submenu. When
parameter level is reached, individual parameters may be selected for adjustment by pressing the adjacent
button. The selected parameter value/s are highlighted, and are adjustable using the rotary encoder.
A parameter may be adjusted simultaneously across multiple channels by selecting all values to be adjusted;
any current value offsets are retained. Some parameters default to multiple selection, with all inputs or
outputs adjusted simultaneously. Changes are effected in real-time and a stored without further confirma-
tion. Pressing EXIT returns to the previous menu level, automatically retaining any parameter changes.