Listing And Code Approvals; Appliance Certification; Additional Related Standards; Gas Pressure Requirements - Heat & Glo SOHO-B-CEB Owner's Manual

Hide thumbs Also See for SOHO-B-CEB:
Table of Contents

Advertisement

1
Listing and Code Approvals
A. Appliance Certification
MODELS: SOHO-B-CEB, SOHO-N-CEB, SOHO-P-CEB
LABORATORY: BSI
TYPE: Gas Fireplace
STANDARD: Latest version of BS EN:613:2001
DIRECTIVE: GAD90/396/EEC
B. Additional Related Standards
The installation must comply with these installation instruc-
tions and all relevant parts of Local and National Building
Standards Regulations and those relevant recommenda-
tions of the following British Standards. BS 5871: Part 1
BS 8303 BS 5440: Parts 1 & 2 BS 6891 BSEN1856 Parts
1 & 2 BS 5482 Part 1, as well as IGE/UP/7.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
The Heat & Glo gas appliances discussed in this Installer's
Guide have been tested to certification standards and listed
by the applicable laboratories.
This appliance must be installed in accordance with the
rules in force.
NOX Class 5 for G20, NOX Class 5 for G31
C. Gas Pressure Requirements
Pressure requirements for SOHO-CEB fireplace are
shown in table below.
Two taps are provided on the right hand side of the gas
control for a test gauge connection to measure the inlet
and outlet pressures.
CAT
Inlet Pressure
Burner Pressure
Gas Rate
Heat Input (Net)
Burner Injector
Pilot Injector
Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum
inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed
upstream from the gas control valve.
8
Natural Gas
(G20)
I
I
I
2H,
2E,
2E+
20 mbar
8,4 mbar
Max. 0,405
/
m3
h
4,0 kW
DMS 50 (1,78 mm)
0,023
Heat & Glo • SOHO-B-CEB, SOHO-N-CEB, SOHO-P-CEB • 2111-980 Rev. i • 3/13
The fireplace and its individual shut-off valve must be dis-
connected from the gas supply piping system during any
pressure testing of the system at test pressures in excess
of 60 mbar.
If the fireplace must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.
WARNING! Risk of Explosion! An in-line regulator
MUST be installed if the gas pressure exceeds 37 mbar.
Failure to install a regulator could damage valve.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 610 meter elevation:
Reduce input rate 4% for each 305 meters feet above
610 meters.
E. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
F. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and burn, whether flame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
All electrical safety testing has been done following the EN
60335-2-102 standard. Local codes apply.
Natural Gas
(G25)
I
2E+
25 mbar
8,4 mbar
Max. 0,405
/
m3
h
3,5 kW
DMS 50 (1,78 mm)
0,023
Butane
(G30)
I
3B/P
37 or 50 mbar
24 mbar
Max. 0,111
/
m3
h
3,6 kW
DMS 61 (1,07 mm)
0,010
Propane
(G31)
I
3P
37 or 50 mbar
24 mbar
Max. 0,134
/
m3
h
3,5 kW
DMS 58 (1 mm)
0,014