D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specified. Framing or finishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).
Combustible Mantels
No mantels are allowed when using Studio-CE fronts.
Note: All dimensions are shown in centimeters
5,1
2,6
12,7
OPENING OF FIREPLACE
Figure 5.3 Minimum vertical and maximum horizontal
dimensions of combustibles above appliance
when using the DF-SOHOCE-BK front.
Combustible Mantel Legs or Wall Projections
TOP VIEW
7,3 cm
MINIMUM
Figure 5.4 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
30,5
27,9
25,4
22,9
20,3
38,1
17,8
35,6
33,0
15,2
30,5
12,7
27,9
10,2
7,6
25,4
22,9
20,3
17,8
15,2
1,3 cm
MINIMUM
UNLIMITED