XANTIA - XM
AUXILIARY EQUIPMENT DRIVE BELT
Engine : XFZ
With air conditioning
Removal :
- Release the bolt (3).
- Keep the dynamic tensioner (1) tensioned by holding the hexagonal fixture «a».
- Release the shoulder of the screw (2) from the oblong hole of the dynamic tensioner.
- Release the dynamic tensioner (1) using the hexagonal fixture «a».
- Remove the belt.
Refitting :
- Locate the dynamic tensioner (1) in its operating position using the hexagonal fixture «a».
(The tensioner (1) will automatically tension it).
- Tighten the screws (2) and (3) to 2.5 m.daN.
B1BP1EXC
68