FILLING THE LP GAS CYLINDER:
Allow only qualified LP gas dealers to properly fill or repair your LP gas cylinder.
New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.
DO NOT allow the cylinder to be filled beyond 80% capacity. Over-filled tanks can create a
dangerous condition. Over-filled tanks can build-up pressure and cause the relief valve to expel
propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or
flame an explosion causing severe burns, bodily harm, or death could occur.
Always use a protective cylinder cap when grill is not connected to cylinder.
If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1
valve and an over-filling prevention device (OPD).
INSTALLING THE LP GAS CYLINDER ONTO THE GRILL:
1. Check that the cylinder valve is closed by turning the knob clockwise.
2. Place the cylinder into the tank holder in the bottom of cabinet.
3. Orient the cylinder such that the valve opening faces the left side table,
so that the hose is not kinked or damaged.
4. Fully tighten the tank retention screw underneath tank holder to secure tank.
5. Attach or detach regulator to the LP gas cylinder only when cylinder is at rest
in tank holder.
HOSE AND REGULATOR:
Your grill is equipped with a Type 1 connection device with
the following features:
1. The system will not allow gas flow from the cylinder until a positive connection
to the valve has been made.
Note:
The cylinder valve must be turned off before any connection is made
or removed.
2. A thermal device that will shut off the gas flow if the device is subject to
temperatures above 240°F to 300°F (115°C to 150°C). If this should happen,
remove the entire regulator assembly and dispose of properly. A replacement
regulator assembly can be purchased by contacting customer service at 800-
527-0717. The cause of the excessive heat should be determined and
corrected before using your grill again.
3. A regulator flow limiting device, when activated, restricts the flow of gas to 10
cubic feet per hour. If the flow limiting device is activated, perform Regulator
Resetting Procedure.
REGULATOR RESETTING PROCEDURE
1. Turn burner control knobs to "OFF", turn off the cylinder valve and disconnect regulator from LP gas tank. Wait
approximately two minutes.
2. Reattach regulator and slowly turn cylinder valve back on. The flow limiting device will now be reset.
WARNING