Internal Lock; Miscellaneous - Epson PhotoPC 3000Z Service Manual

Epson photopc 3000z digital still camera service manual
Hide thumbs Also See for PhotoPC 3000Z:
Table of Contents

Advertisement

EPSON PhotoPC 3000Z

1.2.10 Internal Lock

Internal clock
Internal clock is built-in
Record the shooting date and time on the image
(Month / Day / Year, Hour / Minute / Second)
Date is held by the super-capacitor at the battery exchange.
-When super-capacitor is charged full: date is held for about 2 hours.
-To charge super-capacitor full, at least 4 hours required by battery
connection or AC adaptor connection.
When charging the camera, you do not have to turn the camera on.
(TBD)

1.2.11 Miscellaneous

Lens cap
Removed and installed manually.
NOTE: With lens cap on, you cannot turn on the camera on the
shooting mode. Lens cap prevent the lens from veering out.
Playback and other operations are possible with the lens cover
on.
Internal flash
Auto (pre-flash method auto tone adjustment) / Off / Forced flash / Red
eye reduction / Slow synchro (for night view. user can select either
trailing or leading flash.)
Effective flash range
Normal mode: 0.5 - 2.4m
Macro mode: 0.2 - 0.5m
It causes over-exposure if you take photos with strobe for a
C A U T I O N
subject within 0.2m on macro mode.
Product Descriptions
Functional Specification
Revision A
16

Advertisement

Table of Contents
loading

Table of Contents