12

DISASSEMBLY INSTRUCTIONS

<"Terminal with lock mechanism" Detaching points>
In case of terminal with lock mechanism, detach the terminal as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with lock mechanism.
The terminal with no lock mechanism can be removed by pulling it out.
Check the shape of the terminal and work.
(1) Slide the sleeve and check if there is a locking lever or not.
Sleeve
Locking lever
MUZ-A09YV -
E1
MUZ-A09YVH -
E1
OUTDOOR UNIT
OPERATING PROCEDURE
1. Removing the cabinet.
(1) Remove the screws fixing the top panel. (Photo 1)
(2) Remove the top panel. (Photo 1)
(3) Remove the screw fixing the service panel. (Photo 2)
(4) Pull down the service panel and remove it. (Photo 2)
(5) Remove the screws fixing the cabinet.
(6) Remove the cabinet.
(7) Disconnect the indoor/outdoor connecting wire.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
Photo 2
Screws of
the cabinet
1Slide the sleeve.
2Pull the terminal while
pushing the locking
lever.
MUZ-A12YV -
E1
MUZ-A12YVH -
E1
Screw of the
service panel
Direction to
remove
Hooks
www.ilmalämpöpumput.com
(2) The terminal with this connector is a terminal
with lock mechanism
1Hold the sleeve, and
Connector
Photo 1
Screws of
the top panel
Screws of
the cabinet
34
pull out the terminal
slowly.
PHOTOS
Screws of
the top panel
Service
panel
Back
panel