1.7.10 Setting Configuration Dip Switches - FLIR D-Series Installation Manual

Thermal camera
Hide thumbs Also See for D-Series:
Table of Contents

Advertisement

D-Series Installation Manual

1.7.10 Setting Configuration Dip Switches

The figure below shows the locations of dip
switches SW 1 and SW 2.
Pelco Address: This is the address of the
system when configured as a Pelco device.
The available range of values is from decimal
0 to 255.
Note
From the factory, switch SW 1-9 (Software Override DIP Switch) is set to Off.This setting
determines that software settings will override the dip switch settings. If you wish to use the
dip switches for configuration, you must set SW 1-9 to the On position.
Table 1-1: Dip Switch Address/ID Settings—SW 2
ID
Bit 1
Bit 2
0
OFF
1
ON
2
OFF
3
ON
...
...
255
ON
427-9029-00-12, version 120
SW 1
SW 1-9
SW 2
Bit 3
Bit 4
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
...
...
...
ON
ON
ON
January 2012
1—D-Series Camera Installation
Figure 1-6: D-Series Camera Configuration
Bit 5
Bit 6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
ON
ON
Switch
Position
Off
On
Bit 7
Bit 8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
ON
ON
1-11

Advertisement

Table of Contents
loading

Table of Contents