Installation - Models Ihf033, Ihf045 And Ihf055; Electrical Installation Requirements - IPSO CHM2172N Planning Manual

On-premise laundry planning handbook ihf washer-extractors
Table of Contents

Advertisement

Installation - Models IHF033, IHF045
and IHF055
Ground
The machine must be placed on a flat, solid surface
(metal base, concrete or solid ground). It is
recommended that the machine be anchored on the
provided places (1) in the base, especially in case of a
plinth. Refer to Figure 6.
1
Mounting Bolt Holes
Figure 6
The machine must be placed entirely level. For easy
maintenance it is recommended to keep a minimal
distance of 23.62 in. (600 mm) between the wall and
the back of the machine.
If several machines are placed next to each other, there
should be a minimal distance of 1.18 in. (30 mm)
between each machine.
5-08-53
1
CHM2180N
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electrical Installation Requirements

- Models IHF033, IHF045 and IHF055
Machine with steam heating or boiler fed
machines without additional electrical heating
220V 3AC
Machine with electrical heating
220V 3AC
9 kW
12 kW
15 kW
18 kW
21 kW
24 kW
Table 1
Washer-Extractors
380V 3AC + N
16 A
16 A
380V 3AC + N
25 A
16 A
40 A
20 A
50 A
25 A
50 A
32 A
N/A
40 A
N/A
40 A