Installation And Connection; Ground; Removal Of The Transport Safety; Water Connection - IPSO HC60 Instruction Manual

Technical specifications; installation instructions; operating instructions; maintenance
Table of Contents

Advertisement

Installation and connection

Ground

A

Removal of the transport safety

A
A

Water connection

Water drain

The machine (with rubber feet) must be placed on a fl at, solid bottom (concrete
or fi xed ground). When using a metal socle or with machines with steam heating,
the machine (without feet) must be anchored on the foreseeing points (A) in
the base (bolts M10). (see Dimensions 2).
The machine must be placed entirely level. For easy maintenance it is recom-
mended to keep a minimal distance of 600 mm between the wall and the back
of the machine.
If several machines are placed next to each another, there should be a minimal
distance of 30 mm between each machine.
Important
The bolt pattern for the fi xation of the HC60 machine is foreseen in the
back panel of the cabinet. Put this panel on the fl oor and indicate the
A
holes (see page 7).
The machine is delivered with hoses with 3/4" connections. These hoses fi t the
water inlet valves of the machine and the main water inlet taps. To ensure the
optimal functioning of the water inlet valves, the water pressure on the inlet
should be between 0,5 and 10 kg/cm² (7 and 145 psi). If the pressure is too
low, the cycle time will increase considerably.
In case of boiler fed machines, a minimum of hot water of 90°C should
be available: HC60: 46l. HC65: 55 l.
The machine is equipped with a drain valve with 6/4" outer diameter (50 mm).
This drain valve should be connected to the drain by means of the drain elbow
which is delivered with the machine.
J The diameter of the main drain should be adapted to the water fl ow and the
number of machines. It should be suffi cient to handle at least 80L/min. per
machine.
J It is necessary to connect the main drain at least on one side to an open air-
brake to allow ventilation.
To prevent damage during transportation, the machine has been
equipped with two red transport brackets (A) to eliminate every
possible movement of the tub.
After the machine has been placed level, take off the backpannel
and remove these transport brackets.
Important
The machine must never be activated before removing
these transport brackets.
HC135: 100l. H165: 120l.
HC75: 65 l. HC100: 80l.
3
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hc65Hc75Hc100Hc135Hc165

Table of Contents