CAUTION
Ensure that the machine is installed on a
level floor of sufficient strength and that
the recommended clearances for
inspection and maintenance are provided.
Never allow the inspection and
maintenance space to be blocked.
Surface
The machine must be securely fixed on a flat surface
(metal base, concrete or solid ground). The anchoring
is to be done on the 6 provided places in the holes on
the corner of the base. (See Mounting Bolt Hole
Locations). Refer to Figure 12.
1
Mounting Bolt Holes
Figure 12
The machine must be placed entirely level. For easy
maintenance it is recommended to keep a minimal
distance of 23.62 in. (600 mm) between the wall and
the back of the machine.
If several machines are placed next to each other, there
should be a minimal distance of 1.18 in. (30 mm)
between each machine.
IMPORTANT: The bolt pattern for the fixation of
the IHC012 machine is located in the back panel of
the cabinet. Put this panel on the floor and mark
the holes.