For Your Safety Read Before Lighting; Lighting The Pilot - Vermont Castings A18CFLRN/P Installation And Operation Instructions Manual

Vented gas log set - dragonfire hearth kits
Table of Contents

Advertisement

Create a mixture of equal parts soap and water. Apply to all the joints of the pipe fittings from the gas supply
pipe to the burner. Turn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap
solution applied to the joints, there is a leak. Turn off the gas supply valve and tighten those fittings. Repeat the
above procedure until no bubbles appear in the soap solution. Remember to test all joints.
WARNING: DO NOT USE AN OPEN FLAME TO TEST FOR LEAKS!
NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the
gas supply line.
WARNING: If you do not follow these directions exactly, a fire or explosion may result
causing property damage, personal injury, or loss of life.
Do not try to light any appliance
Do not touch any electrical switch, do not use any phone in your building
Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions
If you cannot reach your gas supplier, call the fire department
Before operating, smell all around the appliance area for gas odor. Be sure to smell near the floor because
some gases (propane) are heavier than air and will "pool" on the floor.
Use only your hand to push or turn the gas control dial. NEVER USE TOOLS. If the knob will not push in
or turn by hand, don't try to repair it, call a qualified technician. Force or attempted repair may result in a
fire or explosion.
The pilot will resist lighting on new installations
due to air in the gas supply line. It may take sev-
eral minutes to bleed air completely out of the gas
plumbing system through the pilot line.
This appliance has a pilot which is lit by a spark igni-
tion device (piezo). If the piezo fails, then light the pilot
using matches following the Match Lighting instruc-
tions below.
1) STOP! Read the safety information above.
2) Push in gas control knob slightly and turn clockwise
to "OFF".
3) NOTE: Knob cannot be turned from "PILOT" to
"OFF" unless knob is pushed in slightly. Do not
force.
4) Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow the safety information
above. If you don't smell gas, go on to the next step.
5) Turn the control knob counterclockwise
LOT" and push in. Continue to hold the control knob
20003903
Leak Test Procedures

For Your Safety Read Before Lighting

WHAT TO DO IF YOU SMELL GAS

Lighting the Pilot

to "PI-
in and push the piezo igniter button in until the pilot
lights.
6) Continue to hold the control knob in for about one (1)
minute after the pilot is lit. Release the knob and it
will pop back up. Pilot should remain lit. If it goes out,
repeat steps 3 and 4.
7) If the knob does not pop out when released, stop and
call your service technician or gas supplier. If the pilot
will not stay lit after several tries, turn the gas control
knob to "OFF' and call your service technician or gas
supplier.
8) Turn gas control knob counterclockwise
"ON". CAUTION: Be sure ON/OFF/RS switch is in the
off (middle) position. Also, the GWSK should be in
the "OFF" position and/or the remote should be in the
"OFF" position before turning the control knob "ON".
If pilot goes out, repeat steps 4 and 5.
9) Turn ON/OFF/RS switch to "ON" or remote position.
Turn remote switch to "ON".
10) Flame is adjustable by rotating the "HI/LO" knob.
to
9

Advertisement

Table of Contents
loading