Replacing The Nozzle Seal - WAGNER AC 4600 Operating Manual

Aircoat spray guns for flat - and round jet nozzles
Hide thumbs Also See for AC 4600:
Table of Contents

Advertisement

EDITION 02/2009
OPERATING MANUAL
6.5

REPLACING THE NOZZLE SEAL

Defective nozzle seal!
Material sprays into the air cap next to the nozzle
Risk of contamination
Do not clean the nozzle seal with sharp-edged objects.
Replace the nozzle seal if the sealing surface is damaged.
SIHI_0021_GB
1. Finishing work and cleaning.
2. Relieve spray gun and unit pressure.
3. Secure gun with trigger safety catch.
4. Unscrew the union nut with nozzle guard (33).
5. Remove air cap (36) and nozzle (13).
6. Carefully release the nozzle seal (17) with the help of a screwdriver.
7. Fit new nozzle seal to valve housing (16).
8. Continue assembly in the reverse order.
PART NO. DOC394871
CAUTION
14 (F)
16
17
13
36
B_02707
33
AC 4600 Pro
32