Installation Service Notices For Installation - Gree Split Air Conditioner Owner's Manual

Hide thumbs Also See for Split Air Conditioner:
Table of Contents

Advertisement

Installation service- Notices for installation
1. The unit installation work must be done by qualified personnel according to the local rules
and this manual.
2. If the air conditioner has not plug, directly connect it into the fixed circuit, a breaker should be
installed in the fixed circuit. all pole of this breaker should be switching off and the distance
of the contact should be at least 3mm.
Basic Requirements For Installation Position
Install in the following place may cause malfunction. If it is unavoidable contact with
service center please:
Place where strong heat sources, vapors, flammable gas or volatile object are emitted.
Place where high-frequency waves are generated by radio equipment, welders and
medical equipment.
Place where a lot of salinities such as coast exists.
Place where the oil (machine oil) is contained in the air.
Place where a sulfured gas such as the hot spring zones is generated.
Other place with special circumstance.
1. The air inlet and outlet vent should be far from the obstruction, make sure that the air can
be blown through the whole room.
2. Select a position where the condensing water can be easily drained out, and the place is
easily connected for outdoor unit.
3. Select a location where the children can not reach.
4. Can select the place where is strong enough to withstand the full weight and vibration of
the unit. And will not increase the noise.
5. Be sure to leave enough space to allow access for routine maintenance. The height of the
installed location should be 230 cm or more from the floor.
6. Select a place about 1m or more away from TVset or any other electric appliances.
7. Select a place where the filter can be easily taken out.
8. Make sure that the indoor unit installation should accord with installation dimension
diagram requirements.
1. Select a location from which noise and outflow air emitted by unit will not inconvenience
neighbors, animals, plants.
2. Select a location where there should be sufficient ventilation.
3. Select a location where there should be no obstructions cover the inlet and outlet vent.
4. The location should be able to withstand the full weight and vibration of the outdoor unit
and permit safe installation.
5. Select a dry place, but do not expose under the direct sunlight or strong wind.
6. Make sure that the outdoor unit installation dimension should accord with installation
dimension diagram, convenient for maintenance, repair.
7. The height difference of connecting the tubing within 5m, the length of connecting the
tubing within 10m.
8. Select a place where it is out of reach for the children.
9. Select a place where will not block the passage and do not influence the city appearance.
Important Notices
Indoor Unit Installation Position Selection
Outdoor Unit Installation Position Selection