PLUG OVEN IN
(NORMAL DISPLAY)
PREHEAT TEMP = 270 C
PRESS TO
PREHEAT
CHANGE
PROGRAM
TEMP
Yes
Error Code
Appears
Operational
Code Appears
No
(NORMAL DISPLAY)
PREHEAT TEMP = 270 C
PRESS TO
PREHEAT
CHANGE
PROGRAM
TEMP

Troubleshooting

POWER UP CONDITION
No
1. Refer To Display
Diagnostics Page 19
2. Clear Error History
After Oven is Repaired
1. Refer To Operational
Codes Pages 17-18
Go to PREHEAT Condition
14
1. No Line Voltage
2. Inoperative Power Cord
3. Inoperative Fuse (F1)
4. Inoperative Touch Screen
5. Inoperative Main Control Board
6. Inoperative Display Board / Filter Board
7. Inoperative -24 Volt Power Board
8. Broken or Loose Wire Connection
9. Open Cavity TCO