Cabling Assembly

Connect power lines and if you have external devices such as sensors and alarms, make the connection
from the general I/O terminal block.
Top View
For Ethernet
For Power & IO Cables
Cable

Waterproof Connector

Assembling Steps
1. Disassemble the components of the waterproof
connector into parts (A) ~ (F) as shown above.
2. Place the screw nut (E) on the Power and GPIO
opening.
3. Feed the power cables through the waterproof
connector (F --> E --> D --> B --> A) as the
illustration shows. Then connect the power
cables to the power source. Note: There are 8
holes on the seal (D), and the widest holes with
a crack on the side are specific for power cables.
4. If you have external devices such as sensors
and alarms, feed the cables through the
1
2
3
Power and IO cables pass through a waterproof connector. The
Ethernet cable should be routed through a rubber seal plug. All
cables are user-supplied.
The max. load for power output pin 8, 12V DO, is 50mA.
Sealing Nut (A)
Housing (B)
Seals (C)
Seal (D)
Screw Nut (E)
Hex Nut (F)
EN - 4
Pin Definitions
4
5
6
7
8
waterproof connector (F --> E --> D --> B -->
A) as previously described. Refer to the pin
definition to connect them to the general I/O
terminal block. Note: The recommended cable
gauge is 2.0 ~ 2.8 mm.
5. Push the seal (D) into the housing (B).
6. Insert the seals (C) into unused holes on the
seal (D) to avoid moisture.
7. Secure the sealing nut (A) tightly and hex nut
(F) from the bottom of the camera.
1
DC 12V-
2
DC 12V+
3
AC24V_2
4
AC24V_1
5
DI- (GND)
6
DI+
7
DO-
8
DO+ (+12V)
(A)
(B)
(D)
(E)
(F)