Cooling/Heating Sleep Mode - GE AS0CD09 Series Technical Service Manual

Split system air conditioner indoor/outdoor units
Table of Contents

Advertisement

7. Cooling or Heating Mode with Sleep Mode Auto Control
When selecting the Cooling ( ), or Heating ( ), combined with the Sleep Mode Auto Control (
diagram is as listed below.
•Cooling Mode with the Sleep Mode
The setting temperature will be automatically increased by 2
INTAKE AIR TEMP.
0
SETTING TEMP. +1 F
(Compressor ON)
0
SETTING TEMP. -1 F
(Compressor OFF)
INDOOR FAN SPEED
COMPRESSOR
•Heating Mode with the Sleep Mode
The operation can be set to stop after 1,2,3,4,5,6, or 7 hours.
INTAKE AIR TEMP.
0
SETTING TEMP. +6 F
(Compressor OFF)
SETTING TEMP.
(Compressor ON)
INDOOR FAN SPEED
COMPRESSOR
30 MINUTES
More than
3 Minutes
Low
Low
OFF
ON
More than
3 minutes
Med
Low or OFF
ON
OFF
0
F 30 minutes later and by 4
0
2 F
More than
3 Minutes
Low
Low
ON
OFF
More than
3 minutes
Med
Low or OFF
ON
OFF
14
), the operation
0
F 1 hour later.
30 MINUTES
0
2 F
Low
ON
More than
3 minutes
Low or OFF
Med
ON
OFF

Advertisement