OUTDOOR UNIT

Connector Type
CN-POWER
RY-COMP
terminal
CN-TRANS
CN-FAN
The connecting
wire of CN-
DC/DC, and
Indoor and
Outdoor Unit
4
3
2
1
Condition
Open
Connecting reversely
Open
Connecting reversely
Open
Open
Open
Connecting error
( 1
2 )
Connecting error
( 1
3 )
Connecting error
( 1
4 )
Connecting error
( 2
3 )
Connecting error
( 2
4 )
Connecting error
( 3
4 )
47
Indicator
All Functions stop.
The operation with the remote controller,
forced and test one do not operate
PWB pattern is damaged when applying the power
All functions stop or the compressor does not operate.
The operation with the remote controller, forced and test
one do not operate.
All Functions stop.
The operation with the remote controller,
forced and test one do not operate
All Functions stop.
The operation with the remote controller,
forced and test one do not operate
The Indoor fan does not operate
All Functions stop.
The operation with the remote controller,
forced and test one do not operate
The only signal of remote controller operation/stop is
inputted, but the unit does not operate.
The RED indicator of outdoor unit blinks 5 times after
2 minutes with applying the power.
The beep sound, such as "beep,beep,beep,beep,
beep", occurs periodically in Indoor unit.
The signal input of a remote controller and operation
of product is impossible.
The RED indicator blinks 5 times after 2 minutes
with applying the power.
The signal of the remote controller is inputted, but
the unit does not operate.
The RED indicator blinks 5 times after 2 minutes
with applying the power.
No power for Indoor unit.
The signal input of the remote controller and
operation of unit is impossible.
The thermal protector of the Power Trans
operates when let it alone for along time.
The signal of the remote controller is inputted.
The fuse and Q61 in the Outdoor unit are damaged
when the indoor fan is operated.
No power for Indoor unit.
The signal input of the remote controller and operation
of unit is impossible.
The RED indicator of the Outdoor unit blinks 5 times
after 2 minutes wiht applying the power.