Cooling Mode; Dry Mode - GE AIR 116 IN Service Manual & Installation Manual

Split system air conditioner
Table of Contents

Advertisement

Function Manual of Remote Controller
7
7 7 7 7 7 . . . . . 1 1 1 1 1
Remote Controller Function Manual
7.1.1 Temperature Parameter
The room set temperature (Tset)
The room ambient temperature (Tamb)
7.1.2 System Fundamental functions

7.1.2.1 Cooling mode

If T
T
+1
, COOL mode will act, the compressor and the outdoor fan will run, the indoor fan will run at the setting speed.
amb
set
If T
T
1
, Compressor and outdoor fan will have a delay of 15 seconds and stop, indoor fan will run at the setting speed
- - - -
-
amb
set
If T
-1
T
T
+1 , the unit will keep running in the old mode.
set
amb
set
In this mode, the 4-way valve will not power on, the setting temp. range:16
7.1.2.1.2 Protection Function
Anti Freezing Protections
When the system tested anti-freezing protection, the compressor will stop, the outdoor fan will delay 15 seconds and stop running .
Over Current protection
When the system is tested, the compressor will stop, the outdoor fan will delay 15 seconds and stop running. The indoor fan will
run at the set speed. When antifreezing protection is eliminated and compressor has stopped for 3min, the system will resume
operation.

7.1.2.2 Dry Mode

7.1.2.2.1 The condition and processes of dehumidifying
When Tamb
Tset+2
, Dry and Cooling modes will act,compressor, outdoor fan will run at setting fan speed.
When Tset-2
Tamb
will stop running, outdoor fan will delay 15s and stop. 3.45 mins later, compressor, outdoor fan and indoor fan motor restart
amb
set
set
Min.
Compressor
Outdoor Fan
Indoor Fan
Setting Fan Speed
Running
Compressor
Outdoor Fan
Indoor Fan
Running
Tset+2
, Dry mode will act, at this time indoor fan runs at low fan speed,compressor will run 6mins and
Start Cooling
Original Running State
Stop Cooling
Min.
Min.
Stop
During anti-freezing
Min.
Setting fan speed
Stop
9
~30
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Air 116 outAir 121 inAir 121 out

Table of Contents