Indoor Unit - GE AS0CD09 Series Technical Service Manual

Split system air conditioner indoor/outdoor units
Table of Contents

Advertisement

(5) Checking the Drainage and
Connecting the cable to

Indoor unit

1) Checking the Drainage
1. Remove the Grille from the cabinet.
Set the up-and-down air direction louver to open position
(horizontally) by finger pressure.
Remove 3 screws
To remove the Grille, pull lower left and right side of the
Grille toward you (slightly tilted) and lift it straight upward
(Four tabs on the top inside edge of chassis are clear of
their slots).
2. Check the drainage.
Pour a glass of water on the evaporator.
Ensure water flows through drain hose of indoor unit to
outdoors.
Grille
29
Chassis
Remove Screws (3 places)