Defrost Control - GE AS0CD09 Series Technical Service Manual

Split system air conditioner indoor/outdoor units
Table of Contents

Advertisement

6. Defrost Control

Defrost operation is controlled by timer and sensing temperature of outdoor pipe.
The first defrost starts only when the outdoor pipe temperature falls below 21
starting of heating operation and more than 10 minutes operation of compressor.
Defrost ends after 12 minutes has passed from starting of defrost operation or when the outdoor pipe temperature
0
rises over 54
F even if before 12 minutes.
The second defrost starts only when the outdoor pipe temperature falls below 21
ending of the first defrost and more than 10 minutes operation of compressor.
OUTDOOR
PIPE TEMP.
0
54 F
(DEFROST OFF)
0
21 F
(DEFROST ON)
INDOOR FAN SPEED
COMPRESSOR
4-WAY VALVE
•Protection of the indoor heat exchanger from frosting
Compressor and outdoor fan stop when indoor pipe temperature is below 32
is above 45
0
F.
More than 60 minutes of
heating operation
More than 10 minutes
running of compressor
ON
ON
ON
13
0
F after 60 minutes has passed from
0
F after 60 minutes has passed from
More than 60 minutes of
Within
heating operation
12 minutes
More than 10 minutes
Defrost
running of compressor
HOT-
START
OFF
ON
OFF
0
F and restart when the pipe temperature
Defrost
OFF
ON
ON
ON
OFF