GE AS05 Series Owner's Manual & Installation Instructions

5,000/6,000/8,000/10,000/12,000/14,000/16,000/18,000/22,000/24,000 btu air conditioners

Advertisement

Safety Information
Safety Precautions . . . . . . . .3
Electricity . . . . . . . . . . . . . . . .3
Operating Instructions
Control Knobs . . . . . . . . .7, 8
Grille and Case . . . . . . . . . . .9
Outdoor Coils . . . . . . . . . . . .9
Air Filter . . . . . . . . . . . . . . . . .9
Installation Instructions
Window Installation-5000
BTU Model (model AS_05)
10, 11-14
6000, 8000, and 10,000 BTU
Models
(models AS_06, AS_08, and
AS_10) . . . . . . . . . . .10, 15-19
12,000, 14,0000, 16,000,
18,000, 22,000, and 24,000
BTU Models
(models AS_12, AS_14,
AS_16, AS_18, AS_22,
and AS_24) . . . . . .10, 20-25
Installation-
Optional All Models . . . . .26
www.geappliances.com
GE Appliances
Before You Call
Normal Operating
Sounds . . . . . . . . . . . . . . . . .27
Customer Service
Product
Registration . . . . . . .2, 29, 30
Warranty . . . . . . . . . . . . . . . .31
Service Telephone
Numbers . . . . .2, Back Cover
E DB68-00951(2)
Owner's Manual &
Installation Instructions
AS_05 - 5,000 BTU models
AS_06 - 6,000 BTU models
AS_08 - 8,000 BTU models
AS_10 - 10,000 BTU models
AS_12 - 12,000 BTU models
AS_14 - 14,000 BTU models
AS_16 - 16,000 BTU models
AS_18 - 18,000 BTU models
AS_22 - 22,000 BTU models
AS_24 - 24,000 BTU models
49-7387-1 JR 12-99

Advertisement

Table of Contents
loading

Summary of Contents for GE AS05 Series

  • Page 1: Table Of Contents

    Use of Extension Cords . . .4 Sounds ....27 Use of Adapter Plugs ..4 AS_05 – 5,000 BTU models Customer Service Operating Instructions Product AS_06 –...
  • Page 2 If you do need service, you can relax knowing help is only a phone call away. A list of toll-free customer service numbers is included in the back section. Or, you can always call the GE Answer Center® at 800.626.2000, 24 hours a day, 7 days a week.
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS Use this appliance only for its intended Turn the mode control OFF and unplug purpose as described in this Owner’s your air conditioner before making any...
  • Page 4: Use Of Extension Cords

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! USE OF EXTENSION CORDS – 115-Volt models only Because of potential safety hazards under certain CAUTION: conditions, we strongly recommend against the use of an extension cord. DO NOT use an extension cord with any of However, if you must use an extension cord, the 230/208 volt models.
  • Page 5: Models With Touch Pads

    About the controls on the air conditioner–models with touch pads. Features and appearance will vary. TIMER TEMP TIMER POWER HIGH MODE ENERGY COOL SAVER ENERGY SAVER on/off HIGH COOL CIRCULAIRE MODE CIRCULAIRE Air Conditioner Controls Remote Control Controls ON/OFF Pad ENERGY SAVER Pad Controls the fan.
  • Page 6: About The Controls On The Air Conditioner–Models With Touch Pads

    About the controls on the air conditioner–models with touch pads. When the air conditioner is turned on, it will Lights beside the touch pads on the air conditioner automatically start in the setting last used. control panel indicate the selected settings. COOL Mode Use the COOL mode with HIGH, MED or LOW fan for Cooling Descriptions...
  • Page 7: Models With Control Knobs

    About the controls on the air conditioner–models with control knobs. Features and appearance will vary. HIGH HIGH COOL COOL COOL COOL COOL COOL MED COOL COOL MODE CONTROLS Your model will have one of the above type controls. TEMP CONTROLS Your model will have one of the above type controls.
  • Page 8 About the controls on the air conditioner–models with control knobs. Additional controls and important information. Energy Saver (on some models) OFF — The fan runs all the time, while the The energy saver switch controls the fan. compressor cycles on and off. ON —The fan and compressor cycle on and off together.
  • Page 9: Care And Cleaning Of The Air Conditioner

    The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet. Air Filter The air filter behind the front grille should be Clean the filter with warm, soapy water.
  • Page 10: Before You Begin

    Preparing to install the air conditioner–All models. Read these instructions completely and carefully. Before You Begin NOTE TO INSTALLER: Leave these instructions with CAUTION: the air conditioner after installation is completed. Do not, under any circumstances, cut or remove the third (ground) prong from the NOTE TO CONSUMER: Keep this Owner’s Manual power cord.
  • Page 11 Window Installation Instructions for 5000 BTU Units (model AS_05) Parts Included Window sash seal Top mounting rail Foam top window gasket Top mounting rail seal strip Left accordion AS_05 panel Right air conditioner accordion panel Security bracket (3) Type A (9)
  • Page 12: Window Installation

    Window Installation Instructions for 5000 BTU Units (model AS_05) Read completely, then follow step-by-step. Window Requirements These instructions are for a standard double- hung window. You will need to modify them for other types of windows. The air conditioner can be installed without the accordion panels if needed to fit in a narrow window.
  • Page 13 Prepare the Air Conditioner Remove the backing from the top mounting Loosen the lower screw on each side of the case rail seal strip and attach it to the bottom of the and hook a security bracket on each side. top mounting rail.
  • Page 14 Window Installation Instructions for 5000 BTU Units (model AS_05) Install the Air Conditioner in the Window Cut the window sash seal to the window Extend the left and right accordion panels width and stick the adhesive side to the to the vertical window sashes and attach bottom of the sash.
  • Page 15 Window Installation Instructions for 6000, 8000, and 10,000 BTU Units (models AS_06, AS_08, and AS_10) Read the section Preparing to Install the Air Conditioner before beginning. Parts Included Top mounting rail Window sash seal Left accordion Foam top panel window gasket Top mounting rail seal strip Right...
  • Page 16: As_10

    Window Installation Instructions for 6000, 8000, and 10,000 BTU Units (models AS_06, AS_08, and AS_10) Read completely, then follow step-by-step. Window Requirements These instructions are for a standard double- All supporting parts must be secured to firm wood, masonry or metal. hung window.
  • Page 17 Remove the Air Conditioner From the Case Remove the 2 screws on each side of the case. Slide the air conditioner from the case by Keep these for later use. gripping the base pan handle and pulling forward while bracing the case. Remove packing cardboard and tape if present.
  • Page 18 Window Installation Instructions for 6000, 8000, and 10,000 BTU Units (models AS_06, AS_08, and AS_10) Install the Case in the Window Cut the window sash seal to the window width Locate the 3 screw holes along the bottom front and stick the adhesive side to the bottom of edge of the case.
  • Page 19 Install the Air Conditioner in the Case Slide the air conditioner into the case. Attach the front grille to the case by inserting the Reinstall the 2 screws removed earlier on each tabs on the grille into the slots on the front of the side of the case.
  • Page 20 Window Installation Instructions for 12,000, 14,000, 16,000, 18,000, 22,000, and 24,000 BTU Units (models AS_12, AS_14, AS_16, AS_18, AS_22, and AS_24) Read the section Preparing to Install the Air Conditioner before beginning. Parts Included Window sash seal Top mounting rail Left accordion Foam top...
  • Page 21 Read completely, then follow step-by-step. Window Requirements These instructions are for a standard double- hung window. You will need to modify them for other types of windows. The air conditioner can be installed without the accordion panels if needed to fit in a narrow ″...
  • Page 22 Window Installation Instructions for 12,000, 14,000, 16,000, 18,000, 22,000, and 24,000 BTU Units (models AS_12, AS_14, AS_16, AS_18, AS_22, and AS_24) Remove the Air Conditioner From the Case Remove the 2 screws on each side of the case. Slide the air conditioner from the case by Keep these for later use.
  • Page 23 Prepare the Window Cut the window sash seal to the window width Mark the centerline of the stool. Measure and and stick the adhesive side to the bottom of mark the locations for the support assemblies ″ from both sides of the centerline. the sash.
  • Page 24 Window Installation Instructions for 12,000, 14,000, 16,000, 18,000, 22,000, and 24,000 BTU Units (models AS_12, AS_14, AS_16, AS_18, AS_22, and AS_24) Install the Case in the Window Carefully slide the case into the window until Extend the left and right accordion panels to the bottom mounting rail drops into the the vertical window sashes and attach the top channels in the support assemblies.
  • Page 25 Install the Air Conditioner in the Case Slide the air conditioner into the case. Attach the front grille to the case by inserting the Reinstall the 2 screws removed earlier on each tabs on the grille into the slots on the front of the side of the case.
  • Page 26: Through The Wall

    Through the Wall Installation Instructions–Optional for All Models The case may be installed through the wall in both existing and new construction. Read completely, then follow step-by-step. IMPORTANT Through the wall installation is not appropriate if any of the side louvers in the case will be obstructed by the wall.
  • Page 27: Troubleshooting Tips

    Before you call for service… Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do Air conditioner • Make sure the air conditioner plug is pushed The air conditioner does not start is unplugged.
  • Page 28 Notes...
  • Page 29 You can rest easy, knowing that all your valuable household products are protected against expensive repairs. 800-626-2224 Place your confidence in GE and call us in the U.S. toll-free at for more information. *All brands covered, up to 20 years old, in the continental U.S.
  • Page 30: Registration

    Our service number is information, call the safety modification. ® 800 GE CARES GE Answer Center (800-432-2737). 800.626.2000. Model Number Serial Number Important: If you did not get a registration card with your...
  • Page 31: Air Conditioner Warranty

    All warranty service provided by our Factory Service Centers, or an authorized Customer Care technician. For service, ® call 800-GE-CARES. For The Period Of: We Will Replace: One Year Any part of the air conditioner which fails due to a defect in materials or workmanship.
  • Page 32: Parts And Accessories

    Expert GE repair service is only a phone call away. Special Needs Service 800.626.2000 800-TDD-GEAC (800-833-4322) GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons with limited mobility. Service Contracts 800-626-2224 Purchase a GE service contract while your warranty is still in effect and you’ll receive a substantial discount.

Table of Contents