SCHOLTES B 40 L EC.1 SF Operating Instructions Manual page 8

Table of Contents

Advertisement

Gas Hob Operating Instructions
Models: B 40 L EC.1 SF
Gas Appr. No: GSCS20141
Rapid
Semi Rapid
Aux
Total
220-240V AC 50/60Hz 0.6W
* By-pass setting on natural gas is adjusted and displayed electronically. No adjustment is required for
ULPG.
 
~ WARNING 240V. DISCONNECT POWER BEFORE SERVICING THE UNIT.
~ TO BE INSTALLED ONLY BY AN AUTHORISED PERSON
A Auxiliary burner
B Semi-rapid burner
C Rapid burner
E Ignitor for gas burners
F Safety device Activates if the flame accidentally
goes out (spills, drafts, etc.), interrupting the
delivery of gas to the burner.
Scholtes
Natural Gas
1.0kPa
Injector
By-pass*
1.29
#3
1.1
#3
0.8
#4
ULPG
2.75kPa
MJ/h
Injector
By-pass*
8
0.8
Closed
6
0.64
Closed
3.2
0.5
Closed
23.2
Page 8 of 16
MJ/h
8.5
5.3
3.1
22.2
Made in EU