Lamp Replacement Procedure - JVC LX-P1010ZU Service Manual

Lcd data projector
Hide thumbs Also See for LX-P1010ZU:
Table of Contents

Advertisement

LX-P1010ZU/ZE

1.4. Lamp replacement procedure

Caution:
Because of possibility of injury, strictly follow the replacement
procedure below.
1. After the cooling fan has stopped, and STANDBY(R) ON(G)
indicator turns solid red, unplug the power cord.
Note:
Please wait more than one hour for lamp replacement.
[ If you need to replace the lamp more urgently ]
The LCD Projector has a forced cooling feature. After the POWER
switch is turned OFF, and sometime during about the first
minute of the normal cooling fan operation, press MENU for 5
seconds. The cooling fan will change to high speed for about
10 minutes. (The "C-d" STATUS CODE will be displayed.)
2. Loosen 2 screws (A) using a screwdriver as shown in Fig. 1-4-1.
3. Remove the Lamp Cover Unit.
4. Push the portion (a) of the Lamp Hold Lever to the direction of
the arrow as shown in Fig. 1-4-2 and release the Lamp Hold
Lever from the Fastening Hook.
5. Carefully pull the Lamp Unit.
WARNING:
• The lamp may be hot. Be careful when handling.
CAUTION
• High-pressure lamp may explode if improperly handled.
• Danger of injury due to lamp fragments.
3 (PA014)
Fig. 1-4-1
Fig. 1-4-2
6. Install the new Lamp Unit.
CAUTION
• Make sure that the Lamp Hold Lever is in the original position
as shown in Fig. 1-4-2.
• Properly dispose of old Lamp.
7. Replace 2 screws (A) using a screwdriver as shown in Fig. 1-4-1.
8. Plug the power code.
9. Press POWER and INPUT buttons together for about 5 seconds
when lighting up red by POWER LED to reset lamp time.