A smeer of oil has to be put on the seal of the filter before
fitting the filter. The filter should be fastened manually:
when the rubber touches the metal turn 3/4 further.
Fig. 18
4.2.6
Readjustment V-beltplacing oil filter
The alternator bracket allows for readjust of the V-belt.
Deflections should be 10 mm (refer to fig. 19)
Fig. 19
EN / W-SQ12 for mobile applications / January 2009
4.2.7
The interval for cleaning of the air filter element (figure 20)
strongly depends on environmental conditions. Check the
condition of the element at least every 500 running hours,
but should be at least every six months.
Fig. 20: Air filter element
4.2.8
The
W-SQ12
with an air strainer element (figure 21). Strainer change
depends on environmental contamination. Check the air
strainer at least every 500 running hours. The strainer can
be cleaned by washing in petrol or solvent
10 mm
Fig. 21
Air filter element
Air strainer element
for mobile applications is standard supplied
MAINTENANCE
23