Supermicro X7SLM+ User Manual page 68

Hide thumbs Also See for X7SLM+:
Table of Contents

Advertisement

X7SLM/X7SLM+ User's Manual
The options are:
The Default Alarm Setting: Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered when the CPU temperature
reaches about 5
o
C above the threshold temperature as predefined by the CPU
manufacturer to give the CPU and system fans additional time needed for CPU
and system cooling.
The Early Alarm Setting: Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered as soon as the CPU temperature
reaches the CPU overheat threshold as predefined by the CPU manufacturer.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vice versa.
Select Workstation if your system is used as a Workstation. Select Server if your
system is used as a Server. Select "Disabled, (Full Speed @12V)" to disable the
fan speed control function and allow the onboard fans to constantly run at the full
speed (12V). The Options are Disabled, 4-pin (Server), and 4-pin (Workstation).
Voltage Monitoring
Vcore, AVCC, 3.3Vcc, 12V, VDIMM, 5V, Chipset 1.5V, 3.3Vsb, and Vbat.
Note: In the Windows OS environment, the Supero Doctor III settings take
precedence over the BIOS settings. When first installed, Supero Doctor III
adopts the temperature threshold settings previously set in the BIOS. Any
subsequent changes to these thresholds must be made within Supero Doc-
tor, since the SD III settings override the BIOS settings. For the Windows
OS to adopt the BIOS temperature threshold settings, please change the
SDIII settings to be the same as those set in the BIOS.
Remote Access Configuration
Remote Access
This feature allows the user to enable the function of Remote Access. The options
are Disabled and Enabled.
If the item Remote Access is set to Enabled, the following items will display:
Serial Port Number
This feature allows the user decide which serial port to be used for Console Redi-
rection. The options are COM 1, and COM 2.
4-14

Advertisement

Table of Contents
loading

Table of Contents