Motion Detection Settings - Mitsubishi Electric DX-NT400E Operation Manual

Digital recorder rs-232c communication capacity
Hide thumbs Also See for DX-NT400E:
Table of Contents

Advertisement

Command codes (continued)
• RS-232C [Direct operation specification] menu setting system command form
<MOTION DETECTION SETTINGS>
Commands name
Commands
DETECTION MASK
<Menu setting>
SETTING
DW,*****
<Inquiry for setting information>
DR,*****
SENSITIVITY
÷
MOTION
÷
THRESHOLD
MD LOCK OUT TIME
÷
Status
<Writing of menu information>
(1)
(2)
*****
RC ≥
(3)
EX,**
DW,*****
<Reading of menu information>
(1)
RC ≥
(3)
EX,**
DR,*****
÷
÷
÷
(1)
*****
:
00533-00724 : CH1
(1)
(2)
*****
00917-01108 : CH3
(2)
*****
:
00000 : OFF
(3)
(1)
(2)
**
: Error type
*****
(1)
*****
:
00501 : CH1
(2)
*****
:
00000 : HIGH • • • • < LOW
00002 : HIGH • • < < < LOW
00004 : HIGH < < < < < LOW
(3)
**
: Error type
(1)
*****
:
00517 : CH1
(2)
*****
: 00001-00192 (point)
(3)
**
: Error type
(1)
*****
:
00284 : CH1
(2)
*****
:
00020 : OFF
00300 : 30 sec
(3)
**
: Error type
Error type : Refer to "Command receive confirmation function".
9
Notes
00725-00916 : CH2
01109-01300 : CH4
00001 : ON
00502 : CH2
00503 : CH3
00504 : CH4
00001 : HIGH • • • < < LOW
00003 : HIGH • < < < < LOW
00518 : CH2
00519 : CH3
00520 : CH4
00285 : CH2
00286 : CH3
00287 :CH4
00050 : 5 sec
00100 : 10 sec
00150 15 sec
00450 : 45 sec
00600 : 60 sec
012000 120 sec

Advertisement

Table of Contents
loading

Table of Contents