Alarms; Table Of Alarm Codes - Electrolux DIVA 45-60-BIG Service Manual

With electronic control edw 503 (functionalities)
Table of Contents

Advertisement

9 ALARMS

When an abnormal situation occurs that may interfere with machine functioning, the main board activates a safety system which in most cases interrupts the
washing cycle. The last three alarm situations are stored in memory. Using a special procedure, service personnel can display all the alarms stored in memory. The
user is only shown four of the alarms in progress.
The END OF CYCLE LED flashes repeatedly.

9.1 Table of alarm codes

No. flashes
Displayed
Type of
of end-of-
to the
Alarm
cycle LED
user
i10
1
yes
i20
2
yes
i30
3
yes
yes
i50
5
SOI/TD 2005-2 PR
Description of the alarm condition
Water fill time-out
(The pressure switch does not close on
FULL after 90 sec. static fill, or never
closes on "FULL" during the initial 60
sec of the dynamic fill at 2800 rpm)
Water drain time-out
(The pressure switch does not return to
EMPTY after two drain phases lasting
120 seconds)
Intervention of Anti-flooding system
(the drain pump switches on)
Motor triac short-circuited
(the washing pump runs uncontrolled at
maximum speed)
Machine status
The drain pump switches on, then
the cycle stops
The drain pump switches on, then
the cycle stops
The cycle is interrupted and the
drain pump switches on
Water fill to level (if necessary),
deactivation of the other
actuators, cycle interrupted. The
washing motor runs at maximum
speed and the alarm is displayed.
17/26
Possible causes
Tap closed; water mains pressure too low; fill
solenoid / wiring faulty; hydraulic circuit of pressure
switch obstructed; level pressure switch / wiring
faulty; circuit board faulty (solenoid triac short-
circuited)
Drain circuit obstructed/blocked; drain pump
interrupted or jammed (foreign bodies); level
pressure switch blocked on FULL (1-3); hydraulic
circuit of pressure switch obstructed; wiring faulty;
circuit board faulty
Water leakage from the tub - sump and various
connections (pump, upper spray arm duct etc.);
floating sensor blocked mechanically; microswitch
faulty; fill solenoid blocked mechanically; circuit
board faulty (solenoid triac short-circuited); wiring
faulty.
Circuit board faulty
599 36 83-66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents