Clearances; Locating Fireplace - Empire Comfort Systems DVP42FP3 Installation Instructions And Owner's Manual

Direct vent gas fireplace heater
Table of Contents

Advertisement

Clearance to Combustibles
Back
Side
Floor
Top Stand-off
Top Framing Edge
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
"
FIRST 3 (SEE MAGNIFIED
VIEW)
TOP FRAMING
LEDGE
GLASS FRONT
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Note: Island (C) and Room Divider
(D) installation is possible as long
as the horizontal portion of the
vent system (H) does not exceed
20 feet with a minimum vertical
run of 8 feet. See details in Venting
Section.
When you install your Direct Vent
Fireplace in (D) Room divider or
(E) Flat on wall corner positions,
a minimum of 6 inches clearance
must be maintained from the
perpendicular wall and the front
edge of the appliance.
Page 8

CLEARANCES

0" (0 mm)
0" (0 mm)
0" (0 mm)
0" (0 mm)
3" (76 mm)
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
3"
NAILING
FLANGES
Figure 2

LOCATING FIREPLACE

CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
Mantel Chart (Figure 3)
12" (305mm)
10" (254mm)
15"
(381mm)
13 3/4"
11"
9"
8"
TOP EDGE OF FIREPLACE
Clearances (Figure 4)
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
CABINET
INSTALLATION
ISLAND
INSTALLATION
ROOM DIVIDER
INSTALLATION
Figure 5
MANTEL
COMBUSTIBLE TRIM AND MANTELS
8"
ALLOWED IN SHADED AREA
6"
4 ½"
3 3/4"
3"
2 1/4"
1 ½"
3/4"
7"
6"
5"
4"
3"
Figure 3
(914mm)
Figure 4
FLUSH WALL
INSTALLATION
25664-0-0309