10. Check the U.L. strain relief
clamp to make sure that it is
tight and cannot be turned.
11. Replace the cover on the
terminal block and fasten in
place.
Make sure that the U.L. strain
i
relief clamp is outside the
cover!
The appliance is now ready to be
plugged into the 4 wire receptacle
of the power rating.
Connecting 3 wire power supply
cord
1. Remove the screws from the
cover of the terminal block
located at the top rear of the
appliance.
2. Make sure that there is
a grounding strap.
3. Fix the strain relief clamp to the
angle bracket. Tighten the nut.
4. Loosen the 2 screws labeled L
and the screw labeled N in the
terminal block.
5. Thread the 3 wire cable
through the U.L. strain relief
clamp.
6. Tighten the screws (2.5 Nm) on
the U.L. strain relief clamp so
that the power cord cannot be
moved.
7. Attach the 2 power cord outer
conductors (red and black) to
the 2 terminals labeled L and
the remaining power cord
conductor (white) to the
terminal labeled N.
8. Tighten all 3 screws (3 Nm) so
that the power conductors are
held in place securely.
9. Check the U.L. strain relief
clamp to make sure that it is
tight and cannot be turned.
10. Replace the cover on the
terminal block and fasten in
place.
Make sure that the U.L. strain
i
relief clamp is outside the
cover!
Additional grounding procedure
-
Some local regulations may
require a separate ground.
In such cases, the required
accessory ground wire, clamp
and screw must be purchased
separately.
-
Never ground the dryer to
plastic plumbing lines, gas lines
or water pipes.
Grounding instruction
This appliance must be grounded.
In the event of a malfunction or
breakdown, grounding will reduce
the risk of electric shock by
providing a path of least resistance
for the electric current.
For Canada the dryer comes with a
cord which has an equipment
grounding conductor and a
grounding plug. The plug must be
plugged into an appropriate outlet
which has been properly installed
and grounded in accordance with
all local regulations and ordinances.
d
WARNING
Improper connection of the
equipment grounding conductor
may result in electric shock.
Have the appliance checked by
a qualified electrician or service
technician if you are in doubt as
to whether the dryer has been
properly grounded.

Exhaust air connection

d
WARNING
1. To reduce the risk of fire, this
dryer MUST BE EXHAUSTED
OUTDOORS.
2. To reduce the risk of fire, do
not use the ductwork longer
than recommended.
3. DO NOT use a plastic or
non metal duct with this dryer.
4. DO NOT use a duct smaller
than 4 inches in diameter.
5. DO NOT use exhaust hoods
with magnetic latches.
6. DO NOT exhaust the dryer into
a chimney, furnace cold air
duct, attic, crawl space, or any
other ductwork used for
venting.
7. DO NOT install a flexible duct
in an enclosed wall, ceiling or
floor.
8. DO NOT crush or kink the
duct.
9. Do clean and inspect the
exhaust system on a regular
basis; at least once a year.
10. The exhaust duct must
terminate in a manner to
prevent back drafts or entry of
birds or other wildlife.
The Bosch dryers are intended to
be vented outdoors. To prevent
build up of moisture and
d
accumulation of lint indoors, as well
as to maintain maximum drying
efficiency, it is recommended that
the dryer is vented outdoors.
Exhaust air outlet on the dryer
The dryer is delivered with an
exhaust air outlet on the rear of the
appliance.
To take account of the spatial
requirements and an existing
exhaust air system, the following
connection options are possible for
the exhaust air outlet:
-
on right side of the appliance,
-
on the underside of the
appliance.
d
9