Scan module does not move to the flatbed position

Scan module does not move to the flatbed position
3.1.1.11
3.1.1.11
Scan module does not move to the flatbed position
Scan module does not move to the flatbed position
Cause
Cause
Cause
Cause
SCSI ID is set.
incorrectly
SCSI cable
connection failure
SCSI termination
failure
Power supply-main
control board
connection failure
Power supply fails
Motor-main control
PCBA connection
failure
Motor failure
Refer to section 4.6.
Relevant Unit
Relevant Unit
Relevant Unit
Relevant Unit
Check Method
Check Method
Check Method
Check Method
SCSI ID Switch
Visual check
None
Visual check
None
Visual check
None
Visual check
Power supply
Tester check (+5V,
+24V,
GND)
None
Visual check
Motor
Visual check
Table 3.7
Table 3.7
Table 3.7
Table 3.7
3-11
Maintenance Method
Maintenance Method
Maintenance Method
Maintenance Method
Remark
Remark
Remark
Remark
Set the SCSI ID to
*SCSI ID should be
the correct one.
within the range of
(1,7).
*Each device
attached to the
SCSI bus must have
a different SCSI ID.
Connect the SCSI
None
cable.
See P.3-16.
See section 2.4.2
SCSI signal
connection for
correct SCSI
termination.
Replace the power
None
supply.
Replace the power
None
supply.
Connect the
None
connector.
Replace the motor
None
module.