Toyotomi FF-V30T Installation And Operation Instructions Manual page 23

Vented heating system
Hide thumbs Also See for FF-V30T:
Table of Contents

Advertisement

CHECKLIST
• Check whether the heater has been connected to a
suitable socket.
• Ensure that the fuel is free of water or other
contaminants.
• Check outside the building in order to ascertain that
there is no fuel or obstructions to the free circulation of
air in the area immediately adjacent tothe exhaust
pipe.
• Inspect the inlet air hose for cracks, loose connections
or blockages.
• Check the outlet air hose for cracks, loose connections
or blockages.
• Check the back of the heater to ensure that the airflow
to the air circulation ventilator is notobstructed.
• Inspect the interior of the building to ensure that the
area immediately adjacent to the heater is free of fuel
and objects that may obstruct the free flowof air.
• Check that the room sensor is not exposed to
draughts, direct sunlight or heat radiated directly from
the heater.
• Use a spirit level to check that the heater is level.
If this inspection brings any faults to light, resolve these
problems before using the heater.
Use only water-free high quality pure
Kerosene. Never use gasoline, LPG, camping
gas or other flammable liquids. The use of
these substances may cause explosions or
fire.