No.
Item
6
Air speed
selection
(Continued):
3) In heating operation, the mode changes to [UL] if thermostat
4) If Ta ≥ 25°C when heating operation has started and when
5) In automatic cooling/heating operation, the revolution
6) Self-clean operation
Outline of specifications
Standard
CODE No.
[5d]
0
SW501 (1)/(2)
OFF/OFF
Tap
HEAT COOL HEAT COOL HEAT COOL HEAT COOL
F1
F2
F3
F4
F5
HH
F6
HH
F7
H+
H+
F8
H
F9
H
FA
L+
FB
L+
L
FC
L
FD
UL
SM56
SM80
Tap
F1
610
F2
550
F3
500
F4
450
F5
400
F6
390
F7
370
F8
350
F9
340
FA
330
FB
320
FC
310
FD
250
is turned off.
defrost operation has been cleared, the air conditioner
operates with (H) mode or higher mode for 1 minute after Tc
entered in E zone of cool air discharge preventive control
(Item 7).
frequency of (HH) is set larger than that in the standard
cooling/heating operation.
F5
F4
Tc
(˚C)
Tcj
47
42
F5
When performing self-clean operation after stopping the
cooling operation, the mode becomes [UL] (210 rpm).
Type 1
Type 3
1
3
ON/OFF
OFF/ON
HH
HH
HH
HH
H+
H+, H H+, H
H+
H
H
L+
L+
L
L
L+
L+
L
L
UL
UL
SM110
SM140
Revolution speed (rpm)
630
700
700
590
670
670
530
660
660
470
640
650
450
620
640
440
610
630
410
550
560
380
490
490
370
480
480
350
450
460
330
400
430
320
400
420
250
300
300
However the revolution
frequency is restricted in the
automatic heating operation as
shown in the following figure.
– 29 –
FILE NO. SVM-13010
Remarks
Type 6
Selection of high
6
ceiling type
ON/ON
CODE No.:
[5d] or selection of
HH
HH
high ceiling on P .C.
board SW501
H+, H H+, H
L+, L
L+, L
UL
SM160
700
670
660
650
640
630
580
530
520
490
450
440
300
Tcj:
Indoor heat exchanger
sensor temperature
However only when
the high ceiling
selection is set to
[Standard]
[Self-clean
displayed.
] is