Installation

4-4-10. Drain Hose Installation

Care must be taken when installing the drain hose for
the indoor unit to ensure that any condensate water is
correctly drained outside. The drain hose can be
installed to the right or left side of the base pan.
1. Remove the rubber cap located on the side of
the base pan depending on the situation.
2. Install the drain hose so that its length can be as
short as possible.
Internal diameter of the drain hose should be
the same or slightly bigger than the external
diameter.
Caution :
When not installing the drain pump
Do not give the hose and upward gradient

after the connection port.
This will cause water to flow backwards when
the unit is stopped, resulting in water leaks.
Upward gradient
  
Do not apply force to the piping on the unit side
when connecting the drain hose. The hose should
not be allowed to hang loose from its connection
to the unit. Fasten the hose to a wall, frame or
other support as close to the unit as possible.
Ceiling
4-26
Ceiling
Support pieces
Note : • Give a slightly slant to the drain hose for proper
drainage of condensate.
Note :
• Secure the drain hose with the cable-tie not to
be separated from the unit.
3. Wrap the drain hose with the insulation drain
pipe, the insulation drain A as shown in figure
and secure them. And wrap the other drain tube
outlet with the insulation drain B provided.
Cable-Tie
Insulation
drain B
Caution :
• Must fit tightly against
body without any gap.
When installing the drain pump
If it is necessary to increase the height of the

drain hose somewhat, the portion directly after
75cm. If it is raised higher than 75cm, there
can be water leaks.
75cm or less
Ceiling
Cable-Tie
Insulation
drain pipe
Drain
hose
Insulation
drain A
Samsung Electronics